Systems

Zeiss MP in vivo platform

Zeiss MP in vivo platform

DFG code: INST 152/876-1 FUGG

 

Location: Campus Forschung (N27), room 00.027, ground floor

Laser lines: Pulsed: Tunable 680-1300nm, Fixed 1040nm, CW: 405/445/488/561/639nm

Software: ZEN

MicroscopeZeiss Axio Examiner.Z1 with LSM 980 and Airyscan 2 (upright)
DFG major instrumentation proposal numberINST 152/876-1 FUGG
Objectives

10x Plan-APOCHROMAT

NA: 0.45

WD (=working distance; mm): 2.0


20x Plan-APOCHROMAT

NA: 0.8

WD (mm): 0.55


20x W Plan-APOCHROMAT Corr DIC

Refractive index: 1.33-1.36

NA: 1.0

WD (mm): 2.4


63x Plan-APOCHROMAT Oil DIC

NA: 1.40

WD (mm): 0.19

Detectors

Confocal unit:

- 32x GaAsP

- 2x PMT (UV&NIR)

- Airyscan 2

External:

- 4x NDD-PMT (non-descanned detectors)

Laser lines (nm)
SpectraPhysics InSight X3+680-1030 (tunable)1040  (fixed)
Output power >1.5W at 700nm
>2.4W at 800nm
>3.0W at 900nm
>2.7W at 1000nm
>2.4W at 1100nm
>2.1W at 1200nm
>1.5W at 1300nm
 >3.5W
Repetition rate80MHz +/- 0.5MHz80MHz +/- 0.5MHz
Pulse width<120fs <170fs 


CW: 405 / 445 / 488 / 561 / 639nm

Pinhole sizevariable
SoftwareZeiss ZEN
Filters for fluorescence

For 32+2 channel spectral detection: tunable between 380-900nm

For eyepiece:

Filter system (em.-color, dye): excitation | beamsplitter | emission

  • 49 (blue; AF405, DAPI):
    BP 365 | FT 395 | BP 445/50
  • 38 (green; AF488, GFP):
    BP 470/40 | FT 495 | BP 525/50
  • 43 (red; AF568, mCherry):
    BP 550/25 | FT 570 | BP 605/70

For Airyscan:

  1. BP 420-480 + BP 495-550
  2. BP 420-480 + BP 570-630
  3. BP 420-500 + LP 605
  4. BP 465-505 + BP 525-585
  5. BP 495-550 + BP 570-630
  6. BP 495-560 + LP 660
  7. BP 570-620 + LP 660

For non-descanned detectors (NDD):

Filter system (em.-color, dye): beamsplitter | emission 

  • NDD1 (far-red, AF647, CY5):
    LP | BP 645-710 IR+
  • NDD2 (cyan; CFP):
    LP 490 | BP 485 IR+
  • NDD3 (green, AF488, GFP):
    LP 555  | BP 500-550 IR+
  • NDD4 (red; AF568, mCherry):
    mirror | BP 570-610 IR+
UV-VIS illuminationHXP 120V
Halogen lamp100W 12V
Scanner
  • Variable
  • Multiplex: 4 spots or 8 spots with Airyscan
Actively damped optical tableNewport Smart Table UT2

Gallery

No Images

Tags

Airyscan, Confocal, FRET, Multiphoton, Spectral unmixing, Superresolution, Tunable excitation, Widefield
We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.